No More Spillovers! Unlike other tap timers that simply measure time, this Fill-O-Meter measures volume of water and will automatically turn off when the specific volume of water is dispensed.

We recommend setting up the Fill-O-Meter with either Duotight fittings or Type A Camlocks. Thread tape will be required for the Camlock. Use sparingly as too much plumber's tape can damage the plastic thread. And it is very important to never overtighten!

  • Displays real time flow rate and volume (Liters/Min or Gallons/Min)
  • Accurately measures and controls volumes at flow rates from 1-30L/Min (0.26-7.9Gal/Min)
  • Never overfill or spillover again
  • Splash resistant housing
  • Great for filling pools, tanks, brewery hardware, distilling gear, mixing liquid and many other applications
  • Integrated flow meter and solenoid valve
  • Illuminated display for usage in the evening
  • Integrated sound alarm
  • Easy 1/2" BSP Inlet and Outlet
  • Automatic failsafe - flow is stopped if the unit loses power

Important Notes:
DO NOT flow liquid the wrong direction, it will break the unit.
DO NOT overtighten fittings onto the 1/2" ports.
DO NOT exceed temperatures greater than 40°C through the unit.

Specifications:
  • Flow Range: 1-30L per minute
  • Temperature Range 0°C to 40°C
  • LCD: 3 inch back lit display
  • Housing Material: ABS
  • Input/Output threads: BSP 1/2"
  • Pressure Rating: 0-12bar (0-180psi)
  • Accuracy: +/- 5%

Please Note: Accuracy can be improved with stable flow. Repeated start/stop or variation in water supply can have negative effect on accuracy. If you are noticing innaccurate fill levels, see the instruction manual for calibration instructions.

KegLand Part Number: KL14694

  • Saves time and cleanup from over filling. Works great with RO system.
  • Put the hose in the tank, punch in the amount of gallons I need and walk away.
  • For the price, this thing is pretty great.
  • 5 stars: 2 (33%)
  • 4 stars: 3 (50%)
  • 3 stars: 1 (17%)
  • 2 stars: 0 (0%)
  • 1 star: 0 (0%)
K
Ken S.
Litter vs. Gallon Conversion.

It has been well documented that that this product does not adequately address the metered rates of gallons in comparison to liters. Although the product does provide the choice of units between gallons and liters both choices in the menu give the same units of flow which is accurate with the liter menu choice. This has been a very long standing issue and I do not know why the manufacturer can not make a simple firmware change to make this work as designed and documented. There should be no reason that a user has to recalibrate the unit for gallon measures. Since More Winemaking supports the sale of this product perhaps corporate influence can get this problem corrected permanently.

R
Robert F.
Decent unit once you get it figured out

I don't usually write reviews but I see other reviews mentioning gallon mode not working. I noticed that is the case as well but I was able to easily resolve it. So if you want your unit to work with gallons read on! If you look at the calibration factor the default value is 9.4 “LPM” (the value for the K-factor is pulses per liter not liters per minute). When you change to gallon units the K-factor changes to 2.48. There are 3.78 liters in a gallon of water and 9.4/3.78 is ~2.48. Since liters are in the denominator they should have multiplied that value by 3.78 not divided (a gallon is bigger than a liter so it will need more pulses not less). 9.4*3.78 is 35.53 and if you change the calibration factor to that in gallons mode you get much much closer. Unfortunately this bug means you can’t easily switch between liters and gallons without fixing the calibration factor each time but presumably anyone who wants to use this in gallons mode wouldn’t be switching it to liters very often. In response to Ken Larson’s review; all of his points are spot on in my opinion except his point on calibrating — he makes it sound much more difficult than it needs to be. It only took me a few tries to get a reasonable calibration figure. First of all the value of 35.76 that he came up with is extremely close to what the factory value would have been (the 35.53 from above) had the firmware done the math correctly. But moving beyond that I dialed in my calibration with a few iterations. I have some rubbermaid 1-quart and 1-gallon pitchers (with measuring marks on them) so I used those. I set the Fill-O-Meter to dispense 0.25 gallons (32 oz) of water and saw where it landed on my 1-quart pitcher and adjusted my K-factor based on that. For example if it had dispensed 10 oz of water my K-factor needs to adjust by (32/10) or 3.2. So multiply your K-factor by 3.2 and try again. Repeat until you’re happy with the accuracy then try dispensing a gallon into your 1-gallon container. For me it was spot on to the measuring mark. I landed at 33.86 as my K-factor on my RO system. For the price this thing is pretty great. It takes a little bit of messing around to get it calibrated and dispensing correctly but I feel that anyone should be able to dial it in with a few minutes of trial and error with the process I followed. I would suggest that MoreBeer and KegLand discuss fixing the bug described above and also documenting a more sane calibration process. I would love a unit with an updated firmware that fixes this issue.

R
Ralph A.
Saves time and money on production and cleanup. Was concerned if would work with RO but works great

Well worth being able to fill a 3 gallon container and not sitting while it fills up. Can go do other stuff and not worry its over flowing. I use it with a RO system for making my brew so had to goto kegland site to get directions that would download to an IPhone to calibrate flow x 10. Morebeer directions wouldn’t work was pdf. Once adjusted works like a champ saves time and cleanup from over filling. Haven’t seen a temp reading yet but not worried about that yet

K
Ken L.
Great Bang For the Buck BUT

I have tested two off these units and passed over one thousand gallons through them getting the same results (testing in both using gallons and Liters - I use gallons). I also ran a commercial $750 digital water meter in-line with this unit in order to verify my results. Positive things that I found: - Once calibrated the "set water to be delivered" came within plus or minus 1% of the set value (for a $100 product - very impressive!). - No battery required and memory saves previous settings during a power failure. Problems that takes it down to three stars: -"Temperature" always displays "000 c" - doesn't work - "Instantaneous Value" displays numbers that are not even close to the actual flow rate. - Calibration requires a commercial digital water meter or a precision volume measuring device. Calibration "K-Factor" comes set at "9.4" not close (no instructions on a calculation method) to what you will end up with (mine was 35.76). It is all trial and error and requires a lot of trials to find the best calibration "K-Factor" number. - The 1% accuracy can only be achieved if there is a good quality pressure regulator in front of the "FILL-O-METER". - the inlet and outlet is a British Standard Pipe thread (similar to 1/2" pipe thread but is a straight thread and uses a rubber 0-ring to make the fitting not leak). It would be nice if the manufacture provided connection fittings. In conclusion: - More Beer customer service was top notch! They sent an exchange replacement immediately with a return label for the first one. They offered a full refund if I wanted to return the second unit as well - They were great! - Once calibrated I can set my desired fill hit start and walk away. - This device falls well short of what it is supposed to do but I decided to keep it because for $100 you can not go wrong and it is well worth it.

P
PAUL L.
Works great in liter mode

I love it with the exception that I can only use in in liter mode. When I put it in gallon mode I only get about 2 qts per 5 gallons before it shuts off. I returned the first one got the 2nd one and it works only in liter mode that is saturate. I'm keeping it and using it by converting gallons to liters Would be helpful if they provided a detailed instruction on how to get the gallon function to work correctly No fault of morebeer they were very very helpful.

L
Larry B.L.B.
All I do now is put the hose in the tank punch in the amount of gallons I need and walk away.

The unit is very good it had to be recalibrated when I changed measurements from liters to gallons.

A
Anonymous

What Voltage is the powerpack 110 or 220 or will it work on both?

MoreCoffee!

110v

MoreCoffee!

110 v

MoreCoffee!

The powerpack works 100-240 volts. It is set up for 240 but has a plug adapter for 120 for use in the US.

MoreCoffee!

110 Volts---Will not work on 220

MoreCoffee!

110 in the USA not sure about other countries.

A
Anonymous

Anyone have problems with the meter leaking due to the 1/2” BSP thread? What fittings are you using to ensure that it doesn’t leak?

MoreCoffee!

I used a large quantity of Teflon tape to get mine to stop leaking. That's all really. As for fitting I used a reducer to get a hose fitting from home depot on the inlet side and duotight 1/2" push fitting for the outlet

MoreCoffee!

Enter an answer to this question. 1/2-inch duothing accessories with internal packing and you're done

MoreCoffee!

Yes same problem here I just use a towel to catch the drips. Never figured out how to stop it. Tried mplumbers tape and adjusting the tightness. Neither worked

MoreCoffee!

I used a standard 1/2" copper fitting with thread tape. Don't over tighten the fitting.

MoreCoffee!

I'm using Camlocks on mine so I bought a couple of 1/2" NPT (male) to 1/2" BSP (female) adapters. I put teflon tape on the male end of the adapter that goes into the female camlock but didn't use any on the male BSP threads on the meter. Works a treat.

MoreCoffee!

BSPP fittings can be tricky to seal if you're using NPT fittings. One way to go is to used A Lot of thread seal tape. Hope that helps.

A
Anonymous

Will this work with the BrewRO System?

MoreCoffee!

The minimum flow rate required to measure accurately is 1L (0.26 gal) per minute. If your RO water is flowing slower than that it will not work accurately.

A
Anonymous

Winter 2021?